CONTROLLER BOARDGLMODELS SW470 AND SW490 ARE FOR VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE.MODEL SW470MEDIUM DUTY
10c8"8"6"Operator24"22-1/2"9-3/4"Concrete pad 18"x34" min.1/2" Redhead (4 required.)FenceHinge PinParalle
1111PAD MOUNTING (SW490)1. Measure the gate length and select appropriate “P” dimension from the gate installation table.2. Layout the concrete pad a
12CONTROL ARM ASSEMBLY (SW470)1. Set the control arm stop on the operator in the positions appropriate for the installation (Figure 1).2. Install th
1313INSTALLATIONCONTROL ARM ASSEMBLY (SW490)1. Set the control arm’s close stop on the operator so that its position corresponds with the handling of
1414INSTALLATIONCONTROL ARM ASSEMBLY (SW490) continuedMANUAL DISCONNECTMODEL SW4701. Remove the (2) black knobs securing the control arm to the opera
1515NOTE: Calculated using NEC guidelines. Local codes and conditions must be reviewed for suitability of wire installation. All power wiring should b
1616ON/OFF SWITCH POWER WIRINGNOTE: Before running power wiring refer to wiring specifications on page 15 for correct wire gauges.Secure all electrica
17PROGRAMMING THE RADIO RECEIVERSET SECURITY MODE The Universal Receiver can be used with up to 15 315 MHz rolling code remote controls or PINs in HIG
18Limit Switch “B”Limit Switch “A”Aux switch (optional)Drive ShaftSet Screw18LIMIT SWITCH ADJUSTMENTNOTE: For limit location and configuration refer t
1919RPM SENSOR (HALL EFFECT) ADJUSTMENTNOTE: Normally the RPM sensor (hall effect) does not need adjustment, but may go out of alignment due to shippi
22OPERATOR SPECIFICATIONSCarton Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2Operator Dimensions and Specific
2020The Sequenced Access Management System or SAMS allows the customer more control when managing vehicular entrances to areas such as apartment compl
21SOFT OPEN1 2 3 4 5 6 7 8 9 10 INTERRUPT (SAFETY) LOOP INPUT5 8 9 10 11 12 21ACCESSORY WIRINGAll inputs are normally open and momentary, except the s
OPENCLOSESTOPOPENCLOSESTOPOPENCLOSESTOP22ACCESSORY WIRINGField Wiring Terminals 9 & 5 - Obstruction Open(Edge/Photo Eye Input) Edge Input: See Pro
23CONTROL BOARD ILLUSTRATIONRelay DriveTroubleshooting LEDsJ1 TerminalTroubleshooting LEDsJ5 ConnectorSAMSJ2 ConnectorJ3 ConnectorAux. Relay Drive(not
24CONTROL BOARD PROGRAMMING AND FEATURESMOTOR LEARN FUNCTION (FORCE PROFILE)This function is preprogrammed at factory. If either board or motor is rep
25 LED LED NAME DESCRIPTIONRELAY DRIVE TROUBLESHOOTING LEDSThere are 5 troubleshooting LEDs on relay drives K1 through K5. These LEDs will be illumi
26Min = 0 secMax = 180 secTIMER-TO-CLOSE ENABLEThis switch enables the auto close timer. The timer to close feature works in conjunction with the pote
Master or Standalone Gate Setting27PROGRAM SETTINGS (DIP SWITCH S2)EDGE/PHOTO OPENThis switch (S2-3) selects edge or photo sensor for the gate opening
Operator fails to run.No Stop Control. Check the green LED (D17) on control board. If the green LED is off, check to make sure a stop control has been
Master or Second operator is not functioning properly.Failure to cycle power after setup. The power to each unit must be cycled in order to initiate p
33OPERATOR DIMENSIONS AND SPECIFICATIONSMODEL SW470• 1/2 HP Motor Maximum Gate Weight – 500 lbs. (226.8 kg) Maximum Gate Width – 12 ft. (3.7 m)MODEL
30OPERATOR MAINTENANCENOTES1. Severe or high cycle usage will require more frequent maintenance checks.2. Inspection and service should always be pe
31SINGLE PHASE WIRING DIAGRAM (SW470)DRAWING NUMBER: 01-G1978DATE: 7/29/03REVISION: EECN: 03-0401 NOTES: 1)
32SINGLE PHASE WIRING DIAGRAM (SW490)DRAWING NUMBER: 01-G1979-1DATE: 7/29/03REVISION: EECN: 03-0401 NOTES: 1
33THREE PHASE WIRING DIAGRAM (SW490)DRAWING NUMBER: 01-G1979-3DATE: 7/29/03REVISION: EECN: 03-0401 NOTES: 1)
34CONTROL CONNECTION DIAGRAMS12345678910111213141516R2R1R4R3369#258017OPENCLOSESTOPOPENCLOSESTOPOPENCLOSESTOPFREQ FREQ NOTE: See wiring diagrams shipp
35Refer to the parts lists below for replacement parts available for your operator. If optional modifications and/or accessories are included with you
36ILLUSTRATED PARTS - SW470A4A5A3A1A7A2D9D2D3D12D8D1A6118649133D1075D62D4D5121110D11D714
ITEM PART# DESCRIPTION A1-7 K75-18366 Arm Assembly Kit A1 08-2001 Rod End Fitting A2 10-2011 Gate Bracket A3 70-18618 Extension Arm
38ILLUSTRATED PARTS - SW490A612637E3E2E1E4E5A4A2A1A5A5A3D12D11D10D14D1D12D4D15D5D17D6D9FD854D7D19D2D13D16D18D21D20D3A78
39VARIABLE PARTS - SW490VARIABLE PARTS LIST - SW490 PART PART NO. DESCRIPTION USED ON 20-1050-1T 1PH 1/2HP Base Mnt. 115/230V TEFC SW490-33-
44The SW470 and SW490 are intended for use with vehicular swing gates. The opener can be used in Class I, Class II, Class III and Class IV application
HOW TO ORDER REPAIR PARTSOUR LARGE SERVICE ORGANIZATIONSPANS AMERICAFOR INSTALLATION AND SERVICE INFORMATION,CALL OUR TOLL FREE NUMBER1-800-528-2806ww
55* REFER TO LOOP MANUFACTURER’S INSTRUCTIONS FOR DETAILED INSTALLATION & LOOP WIRING INSTRUCTIONS.DUAL SWING GATE SYSTEMSWING GATE SYSTEMSUGGEST
661. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one comp
71.1 Gates shall be constructed in accordance with the provisions given for the appropriate gate type listed, refer to ASTM F2200 for additional gat
88 Moving Gate Can CauseInjury or DeathKEEP CLEAR! Gate may move at anytime without prior warning.Do not let children operate the gate orplay in the g
9INSTALLATIONPOST MOUNTING (SW470)1. Locate and anchor two posts made of 3" (7.6 cm) outerdiameter heavy walled pipe. Posts should be parallel an
Comentários a estes Manuais